Introduction

Imagine this: Your system suddenly slows down, files start disappearing, and before you know it, your hard drive crashes, taking all your valuable data with it. Sounds like a nightmare, right? This is why disk health monitoring is essential!

SMART (Self-Monitoring, Analysis, and Reporting Technology) is a lifesaver when it comes to predicting potential drive failures before they happen. In this guide, we’ll explore how to use smartctl to keep your disks in check and avoid unexpected failures.

In this guide, we will cover how to test:
1. Standard Drives (SATA/SSD)
2. Hardware RAID Arrays
3. NVMe Disks 

Testing Standard Drives (SATA, SAS, SSDs)

Whether you’re using a traditional hard drive or an SSD, running SMART tests can help detect issues early.

Performing a Long Test (Deep Scan for Errors)

A long test thoroughly scans the entire disk for bad sectors (takes 10+ minutes).

smartctl -t long /dev/sdX # Replace “sdX” with your drive (e.g., sda)

Pro Tip: Use long tests for periodic deep scans.

Performing a Short Test (Quick Health Check)

A short test performs a quick diagnosis (~2 minutes).

smartctl -t short /dev/sdX

Use this when you suspect issues but need a fast check.

Checking Test Results

smartctl -l selftest /dev/sdX # View self-test logs

smartctl -a /dev/sdX # Full SMART report

Healthy Disk: Completed without error
Issues Detected: Failed / Errors → Time to back up your data!

2. Disk Testing for Hardware RAID Configurations

RAID controllers (e.g., Dell PERC, LSI MegaRAID) require special handling since SMART doesn’t work directly on RAID virtual drives.

Check if RAID Controller Supports SMART

smartctl -a -d sat+megaraid,0 /dev/sdX # For MegaRAID

  • Replace 0 with the correct RAID drive ID (check via smartctl –scan).

Performing Tests on RAID Drives

  • Long Test:

smartctl -t long -d sat+megaraid,0 /dev/sdX

  • Short Test:

smartctl -t short -d sat+megaraid,0 /dev/sdX

Checking RAID Test Results

smartctl -l selftest -d sat+megaraid,0 /dev/sdX

smartctl -a -d sat+megaraid,0 /dev/sdX

Note : For other RAID controllers (HP, LSI, Dell), adjust -d parameter (e.g., -d cciss,0 for HP).

3. Disk Testing for NVMe Drives

NVMe drives use different commands than SATA.

Checking Basic SMART Attributes

smartctl -a /dev/nvme0 # Replace “nvme0” with your NVMe device

OR (if smartctl fails):

nvme smart-log /dev/nvme0

Performing Tests on NVMe

  • Long Test:

smartctl -t long /dev/nvme0

  • Short Test:

smartctl -t short /dev/nvme0

Viewing NVMe Test Results

smartctl -l selftest /dev/nvme0

nvme self-test-log /dev/nvme0 # Alternative

Conclusion

Keeping an eye on your disk health can save you from unexpected data loss and system crashes. A few key takeaways:

Regular SMART tests help detect early signs of disk failure.
For RAID, always specify the correct controller type.
NVMe requires different commands than SATA/SSD.

Pro Tip: Set up automated SMART checks so you’re always ahead of potential disk failures. Prevention is always better than cure!

For more insightful guides on website management, check out our blog!